Extractor hood and fireplace in the same room – is that possible?

What do an extractor hood and a fireplace have to do with each other? Quite a lot, when you look at the physical effect. When an extractor hood and a fireplace are operated at the same time, a negative pressure can develop in the room. Since 2006, safety measures for the combined operation of fireplaces and ventilation systems have been mandatory under DIN 1946 Part 6 – 2006 to ensure greater safety.

When there’s not enough air to breathe

What happens when an extractor hood and a fireplace are running at the same time? Quite simply: the fireplace or stove draws in combustion air and directs the exhaust gases outside through the chimney. Under normal conditions, there is an atmospheric overpressure in the room, which is generally unproblematic.

The issue arises when a mechanical ventilation system (such as an extractor hood) operates in a closed and airtight room. It can extract up to 1,000 m³ of air per hour without allowing fresh air to flow back in. This creates a negative pressure of up to -40 Pa, posing a risk both to the occupants and to the fireplace.

Protecting fireplaces

The simplest and most cost-effective way to protect both people and the fireplace is by installing a contact switch on the window. The extractor hood only operates when the window is tilted open. This way, the hood can draw in the required air through the open window.

Another alternative with DIBt approval is the BRUNNER negative pressure safety switch (USA). Its function is very simple: when the stove or fireplace is “cold,” the monitoring remains in sleep mode. As soon as the temperature sensor reaches a preset temperature, a pressure sensor begins measuring the difference between the chimney draft and the room pressure.

Unterdruck-Sicherheitsabschalter
BRUNNER negative pressure safety switch USA

In most cases, this does not lead to a malfunction. However, if a ventilation system or extractor hood does not operate as intended, a negative pressure affecting the burning fireplace is detected, and the source of the disturbance is automatically shut off for safety reasons.

The BRUNNER USA safety device ensures that no toxic CO gases are unintentionally drawn from the fireplace into the living space.

Conclusion

When an extractor hood and a fireplace are operated in the same room, safety measures against negative pressure are mandatory. The BRUNNER negative pressure safety switch (USA) measures the room pressure and automatically switches off the source of interference if negative pressure occurs.

Expert advice

A window contact switch or the negative pressure safety switch is required and useful to prevent or detect negative pressure. With the window contact switch, the window is tilted open when the extractor hood and fireplace are operated at the same time. For those who prefer not to do this, especially during the winter months, the negative pressure safety switch is the better option.

Portrait of Klaus, Head of Customer Service
Klaus Leihkamm, Head of Craftsman Consulting & Customer Service

These articles might also interest you

Tunnelkachelofen mit Ofenbank und Blick auf eine Terrasse
BRUNNER Waterbearing Stove HKD 7 SK Tunnel, Realisation: W. Grabowski GmbH
2. June 2025 | Oven technology, Heating concepts

Water-bearing fireplace or tiled stove – which one is right for me?

With water-bearing fireplaces or tiled stoves, the generated heat can also be used to support the central heating system. Whether...

Floating panorama fireplace as room divider
BRUNNER Fireplace panorama 51-66-50-66 | Realisation: Hofer Bernhard
6. May 2025 | Oven technology

Room divider: fireplace and heat storage stove

Crackling flames, dancing firelight, and a cozy warmth that fills the room with a soft glow. A wood-burning appliance is...

water-bearing tiled stove compact boiler B9 in a rustic room
28. April 2025 | Oven technology

The new compact water-bearing boiler B9

With variable boiler capacity – ideal for retrofit installations

Is there something for you?

Discover our entire product range now

Urfeuer 4 free brennend vor schwarzem Hintergrund